Data Center

The ICFiles Cloud is Hosted with Softlayer an IBM Company

Secure File Share IBM SOC 2 Data Center

There is much more to building and operating a data center than filling a room up with servers. Every aspect of a SoftLayer data center – from power density and redundancy, to capacity and cooling, and location and accessibility – is designed to guarantee its security, resiliency, and efficiency. Secure File Share IBM SOC 2 Data Center

We build each center to the same spec, and equip it to provide the full SoftLayer catalog of services. We are staffed 24×7 with SoftLayer experts to troubleshoot and address the rare issues that can’t be directly resolved through our automated management system. Secure File Share IBM SOC 2 Data center



 

Secure File Share IBM SOC 2 Data centerStandardized Pod Design.

Standardized, best-practices-based facilities.

Each SOC 2 Data center facility features one or more pods that are built to the same specifications with best-in-class methodologies to support up to 5,000 servers. Leveraging this standardization across all geographic locations, we optimize key data center performance variables including: space, power, network, personnel, and internal infrastructure.

 

 


 

Secure File Share IBM SOC 2 Data centerHigh Performance Rack Architecture.

Better power, bandwidth, and support for each server.

We’ve designed our racks to provide high bandwidth, ample power, simplified system deployment, and faster issue resolution. Each rack has 40Gbps of connectivity right to it – 20Gbps to the private network, 20Gbps to the public network – for exceptional and consistent network performance for every system.

 


Redundant, Best-in-Class Infrastructure.

Redundant power, cooling, and network carriers.

All SoftLayer SOC 2 Data centers maintain multiple power feeds, fiber links, dedicated generators, and battery backup. They are built from industry-leading hardware and equipment, ensuring the highest level of performance, reliability, and interoperability.


Audited Physical Security.

24×7 onsite security, SOC II report compliance.

Through automation, rigorous and audited controls, around the clock security, and server room access limited to certified employees, every location is hardened against physical intrusion. Secure File Share IBM SOC 2 Data center


Data Center Specs – Home of ICFiles.com

  Server Capacity Input Power UPS Battery Backup Units Backup Power Generators Redundant Cooling Fire Suppression Access Control
Dallas 05  16,000+ 6mw 12.47kv 6 x 1250kVA 4 x 2mW Liebert 20-ton
HVAC
Pre-action
dry pipe
Proximity
badge
Dallas 07 5,500+ 3,000 amps
480v
4 x 500 kVA 2 x 2mW Trane 125-ton
HVAC
Trane 500-ton
Chillers
Pre-action
dry pipe
Proximity
badge
 

Data Center Specs for Alternate Locations – Available for Private Servers

  Server Capacity Input Power UPS Battery Backup Units Backup Power Generators Redundant Cooling Fire Suppression Access Control
Dallas 06 17,000+ 9,000 amps
480v
8 x 500 kVA
4 x 375 kVA
4 x 2mW Liebert 30-ton
HVAC
Pre-action
dry pipe
Proximity
badge
San Jose 12,000+ 9,000 amps
480v
12 x 625 kVA 4 x 2mW 12 x 130-ton
Chillers
Pre-action
dry pipe
Proximity
badge
Seattle 10,000+ 2,000 amps
480v
4 x 500 kVA 3 x 2mW Liebert 30-ton
HVAC
Pre-action
dry pipe
Proximity
badge
Washington DC 12,000+ 2,000 amps
480v
8 x 750 kVA 3 x 2mW Liebert 30-ton
HVAC
FM-200 with
VESDA
Biometric
 

Data Center Specs Outside the US – Available for Private Servers

  Server Capacity Input Power UPS Battery Backup Units Backup Power Generators Redundant Cooling Fire Suppression Access Control
Amsterdam  8,000+ 13 mW 6 x 800 kVA 4 x 1875kW 4 x 950kW
chillers
Pre-action
dry pipe
Proximity
badge
Singapore 16,000+ 30 mW 12 x 800 kVA 4 x 1875kW 4 x 5.275kW
chillers
Pre-action
dry pipe
Proximity
badge
 